Technical Document
Specifications
Brand
Chauvin ArnouxMultimeter Type
Handheld
Model Number p
CA 5277
Display Type
Digital
Functions Measured
AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Diode, Frequency, Low Impedance Voltage, Resistance, Temperature
Absolute Maximum DC Current Measurement
20A dc
Absolute Maximum AC Current Measurement
10A ac
Absolute Maximum Resistance Measurement
60MΩ
Absolute Maximum AC Voltage Measurement
1000V ac
Absolute Maximum DC Voltage Measurement
1000V dc
Absolute Maximum Temperature Measurement
+1200°C
Absolute Maximum Capacitance Measurement
60mF
Maximum Frequency
20kHz
DC Current Measurement Resolution
1µA dc
AC Current Measurement Resolution
1µA ac
AC Voltage Measurement Resolution
0.01mV ac
Resistance Measurement Resolution
100mΩ
DC Voltage Measurement Resolution
0.01mV dc
Capacitance Measurement Resolution
1pF
Safety Category Level
CAT III, CAT IV
Temperature Measurement Resolution
0.1°C
Best Capacitance Measurement Accuracy
±1 % + 5 digits
Minimum Operating Temperature
-10°C
Height
190mm
Weight
400g
Best DC Current Accuracy
±0.8 % + 2 digits
Best AC Current Accuracy
±1 % + 3 digits
Width
90mm
Safety Category Voltage
CAT III 1000 V, CAT IV 600V
Battery Type
9 V, IEC 6LR61
Best Resistance Measurement Accuracy
±1 % + 2 Digits
Maximum Operating Temperature
+50°C
Length
45mm
Dimensions
90 x 45 x 190mm
Best DC Voltage Accuracy
0.09% + 2 cts
Best Temperature Measurement Accuracy
±0.5 % + 2 °C
Best AC Voltage Accuracy
±1 % + 3 digits
Country of Origin
France
Product details
Chauvin Arnoux CA5277 True RMS Digital Multimeter
The comprehensive CA 5277 multimeter is equipped with all the functions needed for testing, maintenance and inspections
The CA 5277 digital Multimeter is particularly compact, making it very easy to handle.
The CA 5277 is a stand-alone portable digital Multimeter specially designed to combine all the functions for measurement of the following electrical quantities in a single instrument
The double 6000 count display is equipped with a 61 + 2-segment bargraph with dual-mode remnant effect
The bargraph has a central zeroAC Voltage measurement with low input impedance (voltage measurements for electrical and electrical engineering
applications)
What are the key features of the Chauvin Arnoux CA5277 Digital Multimeter?
TRMS AC+DC measurement of voltage and current
12-bit converter
5 measurements / second
CAT IV 600V / CAT III 1000V
IP54
Double 6,000-count backlit display
Bi-mode bargraph with 61+2 segments (full scale/central zero)
Automatic or manual range selection
VLowZ low-impedance voltage measurement with low-pass filter
1,000 V / 10 A
10 μV resolution
Current from 1 μA
Measurement of ionization currents
Resistance / audible continuity
Temperature / Capacitance
μA range for ionization current measurement
Min / MAX (100 ms)
Peak+ / Peak- (1 ms)
Differential measurements (&Delta ;X) et RELative (&Delta ;X/X%)
3-year warranty
Whats included?
1.5 m red straight/elbowed cable
1.5 m black straight/elbowed cable
CATIV 1 kV red test probe, CATIV 1 kV black test probe
Alkaline 6LF22 9 V battery
Multi-fixture mounting accessory
Wire K thermocouple + adapter
Bag 120 x 200 x 60 mm
Quick start guide in 5 languages, operating instructions on CD ROM in 5 languages
Standards
CAT IV 600 V and CAT III 1000 V
Stock information temporarily unavailable.
Please check again later.
€ 532.43
Each (ex VAT)
€ 633.59
Each (inc VAT)
Calibration type
No Calibration
1
€ 532.43
Each (ex VAT)
€ 633.59
Each (inc VAT)
Calibration type
No Calibration
1
Technical Document
Specifications
Brand
Chauvin ArnouxMultimeter Type
Handheld
Model Number p
CA 5277
Display Type
Digital
Functions Measured
AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Diode, Frequency, Low Impedance Voltage, Resistance, Temperature
Absolute Maximum DC Current Measurement
20A dc
Absolute Maximum AC Current Measurement
10A ac
Absolute Maximum Resistance Measurement
60MΩ
Absolute Maximum AC Voltage Measurement
1000V ac
Absolute Maximum DC Voltage Measurement
1000V dc
Absolute Maximum Temperature Measurement
+1200°C
Absolute Maximum Capacitance Measurement
60mF
Maximum Frequency
20kHz
DC Current Measurement Resolution
1µA dc
AC Current Measurement Resolution
1µA ac
AC Voltage Measurement Resolution
0.01mV ac
Resistance Measurement Resolution
100mΩ
DC Voltage Measurement Resolution
0.01mV dc
Capacitance Measurement Resolution
1pF
Safety Category Level
CAT III, CAT IV
Temperature Measurement Resolution
0.1°C
Best Capacitance Measurement Accuracy
±1 % + 5 digits
Minimum Operating Temperature
-10°C
Height
190mm
Weight
400g
Best DC Current Accuracy
±0.8 % + 2 digits
Best AC Current Accuracy
±1 % + 3 digits
Width
90mm
Safety Category Voltage
CAT III 1000 V, CAT IV 600V
Battery Type
9 V, IEC 6LR61
Best Resistance Measurement Accuracy
±1 % + 2 Digits
Maximum Operating Temperature
+50°C
Length
45mm
Dimensions
90 x 45 x 190mm
Best DC Voltage Accuracy
0.09% + 2 cts
Best Temperature Measurement Accuracy
±0.5 % + 2 °C
Best AC Voltage Accuracy
±1 % + 3 digits
Country of Origin
France
Product details
Chauvin Arnoux CA5277 True RMS Digital Multimeter
The comprehensive CA 5277 multimeter is equipped with all the functions needed for testing, maintenance and inspections
The CA 5277 digital Multimeter is particularly compact, making it very easy to handle.
The CA 5277 is a stand-alone portable digital Multimeter specially designed to combine all the functions for measurement of the following electrical quantities in a single instrument
The double 6000 count display is equipped with a 61 + 2-segment bargraph with dual-mode remnant effect
The bargraph has a central zeroAC Voltage measurement with low input impedance (voltage measurements for electrical and electrical engineering
applications)
What are the key features of the Chauvin Arnoux CA5277 Digital Multimeter?
TRMS AC+DC measurement of voltage and current
12-bit converter
5 measurements / second
CAT IV 600V / CAT III 1000V
IP54
Double 6,000-count backlit display
Bi-mode bargraph with 61+2 segments (full scale/central zero)
Automatic or manual range selection
VLowZ low-impedance voltage measurement with low-pass filter
1,000 V / 10 A
10 μV resolution
Current from 1 μA
Measurement of ionization currents
Resistance / audible continuity
Temperature / Capacitance
μA range for ionization current measurement
Min / MAX (100 ms)
Peak+ / Peak- (1 ms)
Differential measurements (&Delta ;X) et RELative (&Delta ;X/X%)
3-year warranty
Whats included?
1.5 m red straight/elbowed cable
1.5 m black straight/elbowed cable
CATIV 1 kV red test probe, CATIV 1 kV black test probe
Alkaline 6LF22 9 V battery
Multi-fixture mounting accessory
Wire K thermocouple + adapter
Bag 120 x 200 x 60 mm
Quick start guide in 5 languages, operating instructions on CD ROM in 5 languages
Standards
CAT IV 600 V and CAT III 1000 V