Technical Document
Specifications
Brand
FlukeAbsolute Maximum Current Measurement
20kA
Absolute Maximum Power Measurement
20mVA
Number of Phases
3
Maximum Voltage
1000V ac
Best Voltage Measurement Accuracy
±0.5 %
Best Current Measurement Accuracy
±1% + 5 Digits
Display Type
LCD
Calibrated
RSCAL
Measurement Type
Current, Energy, Frequency, Harmonic Distortion, Interharmonics, Power Factor, Unbalance, Voltage
Measurement Standards
EN50160
Interface Type
USB
Memory Capacity
7MB
Power Source
Battery
Battery Type
Rechargeable NiMH
Model Number p
434
Battery Life
7 h
Width
169mm
Length
256mm
Maximum Frequency
70Hz
Minimum Frequency
40 Hz
Dimensions
256 x 169 x 64mm
Minimum Operating Temperature
0°C
Height
64mm
Weight
2kg
Maximum Operating Temperature
+50°C
Product details
Fluke 434/PWR Power Analyser Kit
Complete three-phase troubleshooting tool for finding energy waste in commercial and factory buildings and equipment.Number of inputs: 4 voltage and current (3 phases + neutral).Maximum input voltage: 1000 Vrms (6 kV peak).Maximum sampling speed: 200 kS/s on each channel simultaneously.Vrms (AC+DC): 1 … 1000 V.Volt/Amps/Hertz.Dips and swells.Power and energy: Watt, VA, VAR, kWh, kVAh, kVARh, Power Factor / Cos / DPF.Unbalance, Harmonics. & inter-harmonicsAutotrend recording: Up to 450 days.Memory - Screens and Data: 50, shared memory divided between logging, screens and data sets
Supplied with
Rugged soft carry case, i430-Flexipack 4 current clamps, 5 Test leads, BC430 Battery charger eliminator, Power Log Software, OC4USB Optical cable for USB, Colour localization set, user manual pn CD-ROM
Stock information temporarily unavailable.
Please check again later.
P.O.A.
1
P.O.A.
1
Technical Document
Specifications
Brand
FlukeAbsolute Maximum Current Measurement
20kA
Absolute Maximum Power Measurement
20mVA
Number of Phases
3
Maximum Voltage
1000V ac
Best Voltage Measurement Accuracy
±0.5 %
Best Current Measurement Accuracy
±1% + 5 Digits
Display Type
LCD
Calibrated
RSCAL
Measurement Type
Current, Energy, Frequency, Harmonic Distortion, Interharmonics, Power Factor, Unbalance, Voltage
Measurement Standards
EN50160
Interface Type
USB
Memory Capacity
7MB
Power Source
Battery
Battery Type
Rechargeable NiMH
Model Number p
434
Battery Life
7 h
Width
169mm
Length
256mm
Maximum Frequency
70Hz
Minimum Frequency
40 Hz
Dimensions
256 x 169 x 64mm
Minimum Operating Temperature
0°C
Height
64mm
Weight
2kg
Maximum Operating Temperature
+50°C
Product details
Fluke 434/PWR Power Analyser Kit
Complete three-phase troubleshooting tool for finding energy waste in commercial and factory buildings and equipment.Number of inputs: 4 voltage and current (3 phases + neutral).Maximum input voltage: 1000 Vrms (6 kV peak).Maximum sampling speed: 200 kS/s on each channel simultaneously.Vrms (AC+DC): 1 … 1000 V.Volt/Amps/Hertz.Dips and swells.Power and energy: Watt, VA, VAR, kWh, kVAh, kVARh, Power Factor / Cos / DPF.Unbalance, Harmonics. & inter-harmonicsAutotrend recording: Up to 450 days.Memory - Screens and Data: 50, shared memory divided between logging, screens and data sets
Supplied with