Multifunction Testers
Multifunction testers or MFTs are handheld versatile devices used to verify the safety of electrical installations in domestic, commercial, and industrial settings. These installation testers are designed to streamline and simplify electrical testing processes and ensure that fixed wiring is safe and correctly installed to meet relevant local standards and safety requirements
Multifunctio...
Showing 1-20 of 126 products

RS Stock No.: 200-3705Brand: RS PRO
€ 86.73
€ 86.73 Each (ex VAT)
Check stock
1

RS Stock No.: 200-3704Brand: RS PRO
€ 35.82
€ 35.82 Each (ex VAT)
Check stock
1
RS Pro
-
-
No
-
-
-
-
48V
Auto Test
-
-
-
-
-
-
-
37mm
-
-
LCD - Backlit
-
-
-
-
12 V
Battery
-
-
68g
86 x 37 x 28.5mm
86mm
-
-
28.5mm
-

RS Stock No.: 177-9342Brand: RS PRO
€ 1,773.05
€ 1,773.05 1 Kit (ex VAT)
Check stock
1
RS Pro
-
Phase to Earth
Yes
MT-6600
Yes
Yes
1000V
1000V
-
-
-
Bluetooth
1mA
-
-
IP67
145mm
-
-
LCD
CAT III 600V
-
-
+45°C
-
Battery
2000Ω
0Ω
1.6kg
242 x 105 x 145mm
242mm
600V
CAT III
105mm
0°C
Fluke
-
3 Wire
-
1651B
-
Yes
250 V, 500 V, 1000 V
500V ac
Continuity, Wiring Polarity
-
-
UK Mains
200mA
AC Type
BS 7671, EN 61010-I, HD 384, IEC 60364
IP40
125mm
-
Type F - Schuko plug, Type G - British 3-pin
LCD
CAT III 500 V, CAT IV 300 V
-
-
+40°C
AA
Battery, Mains
2000Ω
20Ω
1.5kg
100 x 250 x 125mm
100mm
300 V, 500 V
CAT III, CAT IV
250mm
-10°C
Fluke
-
3 Wire
Yes
1653B
Yes
Yes
50 V, 100 V, 250 V, 500 V, 1000 V
500V ac
Continuity, Wiring Polarity
Yes
Yes
-
200mA
AC Type
EN 61010-I, HD 384, IEC 60364
IP40
125mm
-
Type G - British 3-pin
LCD
CAT III 500 V, CAT IV 300 V
-
-
+40°C
AA
Battery, Mains
2000Ω
20Ω
1.3kg
100 x 250 x 125mm
100mm
300 V, 500 V
CAT III, CAT IV
250mm
-10°C
Fluke
-
-
-
T6-600
-
-
-
600V ac
AC Current, AC Voltage, DC Voltage, Resistance
-
-
-
-
-
-
-
259.3mm
-
-
Digital
-
-
-
+50°C
AA IEC LR6
-
-
-
350g
61.1 x 43.8 x 259.3mm
61.1mm
600V
CAT III
43.8mm
-10°C
Fluke
-
-
Yes
T5
No
-
-
600V ac
AC Current, AC Voltage, Continuity, DC Current, DC Voltage, Resistance
-
-
-
-
-
-
-
203mm
-10 → +50 °C
-
-
CAT III 600 VV
0 → 1000 O
0 to 600V
+50°C
AA x 2
Battery
-
0Ω
300g
30.5 x 51 x 203mm
30.5mm
600V
CAT III
51mm
-10°C
Fluke
-
Phase to Earth, Phase to Neutral
Yes
1662
Yes
No
100 V, 250 V, 500 V, 1000 V
500V ac/dc
Continuity, Frequency, Insulation Resistance, Loop and Line Resistance, Measure Motor Windings, Phase Sequence Test, Prospective Earth Fault Current, Prospective Short Circuit Current, RCD Test, Resistance, Voltage, Wiring Polarity
-
Yes
-
10mA
A, AC
IEC 60364
IP40
125mm
-
UK
-
CAT III 500 V, CAT IV 300 V
-
100 → 1000V
-
AA
Battery
2000Ω
20Ω
1.3 (with Battery)kg
100 x 250 x 125mm
100mm
300 V, 500 V
CAT III, CAT IV
250mm
-
Kewtech Corporation
-
2 Wire, 3 Wire
Yes
KT65DL
Yes
Yes
100V
500V
Continuity
Yes
Yes
USB
200mA
AC Type
EN 61557, IEC 61557
IP40
114mm
-
-
Backlight
CAT III 300 V
-
-
+40°C
AA, LR6
Battery
2000Ω
20Ω
1.4kg
235 x 136 x 114mm
235mm
300V
CAT III
136mm
0°C
Martindale
-
-
-
ET4
-
-
-
600V ac
-
-
-
-
-
-
-
-
44mm
-
-
LCD
CAT III 600V
-
-
+40°C
9V
Battery
-
-
200g
202.5 x 51 x 44mm
202.5mm
600V
CAT III
51mm
0°C
Fluke
-
-
Yes
T5
No
-
-
1000V ac
AC Current, AC Voltage, Continuity, DC Current, DC Voltage, Resistance
-
-
-
-
-
-
-
203mm
-10 → +50 °C
-
-
CAT IV 600 V / CAT III 1000 VV
25 → 400 O
0 to 1000V
+50°C
AA x 2
Battery
1000Ω
0Ω
300g
30.5 x 51 x 203mm
30.5mm
600 V, 1000 V
CAT III, CAT IV
51mm
-10°C
Fluke
-
-
-
T5-600 + 62MAX + 1AC-II
-
-
-
600V ac
AC Current, AC Voltage, DC Voltage, Resistance
-
-
-
-
-
-
-
203mm
-
-
LCD
-
-
-
+50°C
AA
-
-
-
380g
30.5 x 51 x 203mm
30.5mm
600V
CAT III
51mm
-10°C
Fluke
-
Phase to Earth, Phase to Neutral
Yes
1664FC
Yes
-
50 V, 100 V, 250 V, 500 V, 1000 V
500V ac/dc
Continuity, Frequency, Insulation Resistance, Loop and Line Resistance, Measure Motor Windings, Phase Sequence Test, Prospective Earth Fault Current, Prospective Short Circuit Current, RCD Test, Resistance, Voltage, Wiring Polarity
Yes
Yes
BLE, USB
10mA
A/F, AC, B/B+, G, S
IEC 60364
IP40
125mm
-
UK
-
CAT III 500 V, CAT IV 300 V
-
50 → 1000V
-
AA
Battery
2000Ω
20Ω
1.3 (with Battery)kg
100 x 250 x 125mm
100mm
300 V, 500 V
CAT III, CAT IV
250mm
-
Martindale
-
-
-
ET5
-
-
-
600V ac
AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Resistance, Temperature
-
-
-
-
-
-
-
44mm
-
-
LCD
CAT III 600V
-
-
+40°C
9V
Battery
-
-
200g
202.5 x 51 x 44mm
202.5mm
600V
CAT III
51mm
0°C
Fluke
-
-
-
T5-1000 + 1AC-II
-
-
-
1000V ac
AC Current, AC Voltage, Continuity, DC Voltage, Resistance
No
-
-
-
-
-
-
203mm
-
-
-
-
-
-
+50°C
AA
-
-
-
380g
30.5 x 51 x 203mm
30.5mm
600 V, 1000 V
CAT III, CAT IV
51mm
-10°C
...