Multifunction Testers
Multifunction testers or MFTs are handheld versatile devices used to verify the safety of electrical installations in domestic, commercial, and industrial settings. These installation testers are designed to streamline and simplify electrical testing processes and ensure that fixed wiring is safe and correctly installed to meet relevant local standards and safety requirements
Multifunctio...
Showing 1-20 of 126 products

RS Stock No.: 200-3705Brand: RS PRO
€ 86.73
€ 86.73 Each (ex VAT)
Check stock
1

RS Stock No.: 200-3704Brand: RS PRO
€ 35.82
€ 35.82 Each (ex VAT)
Check stock
1
RS Pro
-
-
No
-
-
-
-
48V
Auto Test
-
-
-
-
-
-
-
LCD - Backlit
86mm
12 V
28.5mm
68g
-
Battery
-
-
37mm
-
-
86 x 37 x 28.5mm
-
-
-
-
-
-

RS Stock No.: 177-9342Brand: RS PRO
€ 1,773.05
€ 1,773.05 1 Kit (ex VAT)
Check stock
1
RS Pro
-
Phase to Earth
Yes
Yes
MT-6600
Yes
1000V
1000V
-
-
-
Bluetooth
1mA
-
-
IP67
LCD
242mm
-
105mm
1.6kg
0°C
Battery
0Ω
2000Ω
145mm
+45°C
-
242 x 105 x 145mm
-
-
-
CAT III
600V
CAT III 600V
Fluke
-
3 Wire
-
-
1651B
Yes
250 V, 500 V, 1000 V
500V ac
Continuity, Wiring Polarity
-
-
UK Mains
200mA
AC Type
BS 7671, EN 61010-I, HD 384, IEC 60364
IP40
LCD
100mm
AA
250mm
1.5kg
-10°C
Battery, Mains
20Ω
2000Ω
125mm
+40°C
-
100 x 250 x 125mm
Type F - Schuko plug, Type G - British 3-pin
-
-
CAT III, CAT IV
300 V, 500 V
CAT III 500 V, CAT IV 300 V
Fluke
-
3 Wire
Yes
Yes
1653B
Yes
50 V, 100 V, 250 V, 500 V, 1000 V
500V ac
Continuity, Wiring Polarity
Yes
Yes
-
200mA
AC Type
EN 61010-I, HD 384, IEC 60364
IP40
LCD
100mm
AA
250mm
1.3kg
-10°C
Battery, Mains
20Ω
2000Ω
125mm
+40°C
-
100 x 250 x 125mm
Type G - British 3-pin
-
-
CAT III, CAT IV
300 V, 500 V
CAT III 500 V, CAT IV 300 V
Fluke
-
-
-
-
T6-600
-
-
600V ac
AC Current, AC Voltage, DC Voltage, Resistance
-
-
-
-
-
-
-
Digital
61.1mm
AA IEC LR6
43.8mm
350g
-10°C
-
-
-
259.3mm
+50°C
-
61.1 x 43.8 x 259.3mm
-
-
-
CAT III
600V
-
Fluke
-
-
Yes
No
T5
-
-
600V ac
AC Current, AC Voltage, Continuity, DC Current, DC Voltage, Resistance
-
-
-
-
-
-
-
-
30.5mm
AA x 2
51mm
300g
-10°C
Battery
0Ω
-
203mm
+50°C
-10 → +50 °C
30.5 x 51 x 203mm
-
0 → 1000 O
0 to 600V
CAT III
600V
CAT III 600 VV
Fluke
-
Phase to Earth, Phase to Neutral
Yes
Yes
1662
No
100 V, 250 V, 500 V, 1000 V
500V ac/dc
Continuity, Frequency, Insulation Resistance, Loop and Line Resistance, Measure Motor Windings, Phase Sequence Test, Prospective Earth Fault Current, Prospective Short Circuit Current, RCD Test, Resistance, Voltage, Wiring Polarity
-
Yes
-
10mA
A, AC
IEC 60364
IP40
-
100mm
AA
250mm
1.3 (with Battery)kg
-
Battery
20Ω
2000Ω
125mm
-
-
100 x 250 x 125mm
UK
-
100 → 1000V
CAT III, CAT IV
300 V, 500 V
CAT III 500 V, CAT IV 300 V
Kewtech Corporation
-
2 Wire, 3 Wire
Yes
Yes
KT65DL
Yes
100V
500V
Continuity
Yes
Yes
USB
200mA
AC Type
EN 61557, IEC 61557
IP40
Backlight
235mm
AA, LR6
136mm
1.4kg
0°C
Battery
20Ω
2000Ω
114mm
+40°C
-
235 x 136 x 114mm
-
-
-
CAT III
300V
CAT III 300 V
Martindale
-
-
-
-
ET4
-
-
600V ac
-
-
-
-
-
-
-
-
LCD
202.5mm
9V
51mm
200g
0°C
Battery
-
-
44mm
+40°C
-
202.5 x 51 x 44mm
-
-
-
CAT III
600V
CAT III 600V
Fluke
-
-
Yes
No
T5
-
-
1000V ac
AC Current, AC Voltage, Continuity, DC Current, DC Voltage, Resistance
-
-
-
-
-
-
-
-
30.5mm
AA x 2
51mm
300g
-10°C
Battery
0Ω
1000Ω
203mm
+50°C
-10 → +50 °C
30.5 x 51 x 203mm
-
25 → 400 O
0 to 1000V
CAT III, CAT IV
600 V, 1000 V
CAT IV 600 V / CAT III 1000 VV
Fluke
-
-
-
-
T5-600 + 62MAX + 1AC-II
-
-
600V ac
AC Current, AC Voltage, DC Voltage, Resistance
-
-
-
-
-
-
-
LCD
30.5mm
AA
51mm
380g
-10°C
-
-
-
203mm
+50°C
-
30.5 x 51 x 203mm
-
-
-
CAT III
600V
-
Fluke
-
Phase to Earth, Phase to Neutral
Yes
Yes
1664FC
-
50 V, 100 V, 250 V, 500 V, 1000 V
500V ac/dc
Continuity, Frequency, Insulation Resistance, Loop and Line Resistance, Measure Motor Windings, Phase Sequence Test, Prospective Earth Fault Current, Prospective Short Circuit Current, RCD Test, Resistance, Voltage, Wiring Polarity
Yes
Yes
BLE, USB
10mA
A/F, AC, B/B+, G, S
IEC 60364
IP40
-
100mm
AA
250mm
1.3 (with Battery)kg
-
Battery
20Ω
2000Ω
125mm
-
-
100 x 250 x 125mm
UK
-
50 → 1000V
CAT III, CAT IV
300 V, 500 V
CAT III 500 V, CAT IV 300 V
Martindale
-
-
-
-
ET5
-
-
600V ac
AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Resistance, Temperature
-
-
-
-
-
-
-
LCD
202.5mm
9V
51mm
200g
0°C
Battery
-
-
44mm
+40°C
-
202.5 x 51 x 44mm
-
-
-
CAT III
600V
CAT III 600V
Fluke
-
-
-
-
T5-1000 + 1AC-II
-
-
1000V ac
AC Current, AC Voltage, Continuity, DC Voltage, Resistance
No
-
-
-
-
-
-
-
30.5mm
AA
51mm
380g
-10°C
-
-
-
203mm
+50°C
-
30.5 x 51 x 203mm
-
-
-
CAT III, CAT IV
600 V, 1000 V
-
...