MEAN WELL Switching Power Supply, HRP-150-24, 24V dc, 6.5A, 156W, 1 Output, 120 → 370 V dc, 85 → 264 V ac
Technical Document
Specifications
Brand
Mean WellOutput Voltage
24V dc
Output Current
6.5A
Power Rating
156W
Number of Outputs
1
Input Voltage
120 → 370 V dc, 85 → 264 V ac
Mounting Type
Chassis Mount
Package Type
Enclosed
Length
159mm
Width
97mm
Depth
38mm
Efficiency
88%
Minimum Temperature
-40°C
Weight
610g
Maximum Temperature
+70°C
Distrelec Product Id
16997617
Country of Origin
China
Product details
HRP-150 Series Single Output Power Supply With PFC Function
High efficiency, long life and high reliability
No load power consumption <0.5W
Built-in active PFC function
Built-in constant current limiting circuit
Built-in remote sense function
Short circuit, over load, over voltage and over temperature protection
Withstands 300Vac surge input for 5 seconds
1U low profile 38mm
Power factor correction to EN61000-3-2,-3
EMC compliance to EN55022 class B
Approvals
UL/cUL recognised, TUV, CB
Standards
UL60950-1, TUV EN60950-1
Stock information temporarily unavailable.
Please check again later.
€ 85.17
Each (ex VAT)
€ 101.35
Each (inc. VAT)
1
€ 85.17
Each (ex VAT)
€ 101.35
Each (inc. VAT)
1
Technical Document
Specifications
Brand
Mean WellOutput Voltage
24V dc
Output Current
6.5A
Power Rating
156W
Number of Outputs
1
Input Voltage
120 → 370 V dc, 85 → 264 V ac
Mounting Type
Chassis Mount
Package Type
Enclosed
Length
159mm
Width
97mm
Depth
38mm
Efficiency
88%
Minimum Temperature
-40°C
Weight
610g
Maximum Temperature
+70°C
Distrelec Product Id
16997617
Country of Origin
China
Product details
HRP-150 Series Single Output Power Supply With PFC Function
High efficiency, long life and high reliability
No load power consumption <0.5W
Built-in active PFC function
Built-in constant current limiting circuit
Built-in remote sense function
Short circuit, over load, over voltage and over temperature protection
Withstands 300Vac surge input for 5 seconds
1U low profile 38mm
Power factor correction to EN61000-3-2,-3
EMC compliance to EN55022 class B
Approvals
UL/cUL recognised, TUV, CB
Standards
UL60950-1, TUV EN60950-1