Technical Document
Specifications
Brand
CelducMaximum Load Current
50 A
Mounting Type
Panel Mount
Maximum Load Voltage
480 V ac
Minimum Load Voltage
200 V ac
Maximum Control Voltage
10 V dc
Minimum Control Voltage
0 V
Switching Type
Analogue Control
Control Voltage Range
0 → 10 V
Range
okpac
Number of Poles
1
Terminal Type
Spring
Output Device
Thyristor
Relay Type
Single Phase angle controller
Load Voltage Range
200 → 480V ac
Series
SO4
Maximum Turn On Time
20ms
Dimensions
45 x 58.2 x 27mm
Depth
58.2mm
Operating Temperature Range
-40 → +100°C
Height
27mm
Length
45mm
Minimum Operating Temperature
-40°C
Standards Met
CE, EAC, cURus
Maximum Operating Temperature
+100°C
Country of Origin
France
Product details
Regulator solid state relays
Solid state relays for controlling resistive load power via phase angle control.
Integrated varistors to protect against overvoltage.
Two spring-technology pull-out connectors.
Protection index: IP20.
Standards
EN 60947-4-3; EN 60950
Proportional and Power
€ 272.59
€ 272.59 Each (ex VAT)
€ 324.38
€ 324.38 Each (inc. VAT)
1
€ 272.59
€ 272.59 Each (ex VAT)
€ 324.38
€ 324.38 Each (inc. VAT)
1
Stock information temporarily unavailable.
Please check again later.
quantity | Unit price |
---|---|
1 - 4 | € 272.59 |
5 - 9 | € 265.73 |
10+ | € 264.11 |
Technical Document
Specifications
Brand
CelducMaximum Load Current
50 A
Mounting Type
Panel Mount
Maximum Load Voltage
480 V ac
Minimum Load Voltage
200 V ac
Maximum Control Voltage
10 V dc
Minimum Control Voltage
0 V
Switching Type
Analogue Control
Control Voltage Range
0 → 10 V
Range
okpac
Number of Poles
1
Terminal Type
Spring
Output Device
Thyristor
Relay Type
Single Phase angle controller
Load Voltage Range
200 → 480V ac
Series
SO4
Maximum Turn On Time
20ms
Dimensions
45 x 58.2 x 27mm
Depth
58.2mm
Operating Temperature Range
-40 → +100°C
Height
27mm
Length
45mm
Minimum Operating Temperature
-40°C
Standards Met
CE, EAC, cURus
Maximum Operating Temperature
+100°C
Country of Origin
France
Product details
Regulator solid state relays
Solid state relays for controlling resistive load power via phase angle control.
Integrated varistors to protect against overvoltage.
Two spring-technology pull-out connectors.
Protection index: IP20.
Standards
EN 60947-4-3; EN 60950